Idex-health-science REGLO CPF Digital Version with Settings Menu Manual de usuario

Busca en linea o descarga Manual de usuario para Zapatillas Idex-health-science REGLO CPF Digital Version with Settings Menu. IDEX Health & Science REGLO CPF Digital Version with Settings Menu User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 52
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM
1
English FrançaisDeutsch
Betriebsanleitung
Operating Manual
Mode d‘emploi
English
FrançaisDeutsch
Betriebsanleitung
Operating Manual
Mode d‘emploi
8.12.06 CB/GP/TM
Ventillose
Taumelkolben-
Dosierpumpe
Mikroprozessor
gesteuert
Schutzgrad
IP 30
Antrieb
ISM 321
Kopf 2.5–25 µl/Hub
FMI 009
Keramikkolben
FMI 010
Stahlkolben
Kopf 5–50 µl/Hub
FMI 005
Keramikkolben
Kopf 10–100 µl/Hub
FMI 007
Keramikkolben
Valveless
Rotary Piston
Dispensing Pump
Microprocessor
controlled
Protection rating
IP 30
Drive
ISM 321
Head 2.5–25 µl/stroke
FMI 009
ceramic piston
FMI 010
steel piston
Head 5–50 µl/stroke
FMI 005
ceramic piston
Head 10–100 µl/stroke
FMI 007
ceramic piston
REGLO-CPF Digital
Pompe doseuse
piston rotative
sans soupape
Contrôlée par
microprocesseur
Classe de protection
IP 30
Moteur
ISM 321
Tête 2.5–25 µl/course
FMI 009
piston céramique
FMI 010
piston en acier
Tête 5–50 µl/course
FMI 005
piston céramique
Tête 10–100 µl/course
FMI 007
piston céramique
mit Settings-Menü
with menu settings
avec menu de paramétrage
(settings)
Neu
New
Nouveau
Vista de pagina 0
1 2 3 4 5 6 ... 51 52

Indice de contenidos

Pagina 1 - (settings)

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM1English FrançaisDeutschBetriebsanleitungOperating ManualMode d‘emploiEnglishFrançaisDeutschBetriebsanlei

Pagina 2

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM10Panneau arrière1 RS232 IN (entrée femelle) pour le contrôle de fonction-nement par PC2 RS232 OUT (sor

Pagina 3

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM11Panneau arrière1 RS232 IN (entrée femelle) pour le contrôle de fonction-nement par PC2 RS232 OUT (sor

Pagina 4 - IMPORTANT

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM12Bedienungspanel (*= Settings Seite 13)8 MODE-Taste Betriebsart wählen * default9 Anzeige der aktiv

Pagina 5

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM13settingsokdefaultescapeabcdSteuertasten für Grundeinstellungena settings Einstieg in das Menu b ok

Pagina 6

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM141234567Grundeinstellungen wählen1 Pumpe ausschalten, 5 Sekun-den warten.2 Die settings-Taste gedrückt

Pagina 7

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM15okokokokokokokGrundeinstellungenCyclesAnzahl Dosierungen 0..9999 (0 = Default-Wert, unendlich)Backstep

Pagina 8

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM16okokGrundeinstellungenAutostart konfigurierenAutostart bestimmt das Verhalten nach dem Einschalten, z.B.

Pagina 9

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM17GrundeinstellungenHead Identifikations-Code (ID) des Pumpenkopfes, siehe auch Tabelle Seite 42(25 = Defa

Pagina 10

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM18Réglages de baseInit (Initialisation)En pressant la touche ok, les réglages de base suivants re-prennen

Pagina 11

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM19Setting the stroke volumeEnter the stroke volume in the settings menu (see basic settings, page 17)The

Pagina 12 -  Avant de mettre la pompe

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM2ContentsSafety precautions 5Warranty terms 8Product 9Real panel Mains voltage Changing the fuses 10O

Pagina 13

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM20Pumping by flow rateBefore entering the required flow rate, please ensure that the “Dis-play Speed” in ba

Pagina 14 -  Remarque

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM21ok12Calibrating the flow rateBefore performing a calibration, please ensure that the “Display Speed” in

Pagina 15

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM22Gerändelter EinstellringKnurled adjustment ring Anneau de réglage moletéFixierschraube für SkalenringFi

Pagina 16

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM23Dispensing by volume1 Change the mode to DISP • Volume2 Use the 56 keys for entering the required di

Pagina 17

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM24Calibrating the volume1 Change the MODE to DISP • Volume k Use the 56keys for ente-ring the required

Pagina 18

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM25okdefaultDefault calibration of flow rate 1 Change mode to PUMP • Flow rate.2 Press the CAL/MAX key

Pagina 19

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM26Dispensing by time The dispensing time can be en-tered from 0.1s to 999h.1 Change the mode to DISP•Ti

Pagina 20

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM27escapedefaultdefaultdefaultDispensing by volumewithin a pre-set time1 Change to mode DISP • Volume. E

Pagina 21

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM28escapedefaultdefaultIntermittent dispensing (by volume)Intermittent dispensing by volu-me with a pre-se

Pagina 22

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM29escapedefaultdefaultIntermittent dispensing (by time)Intermittent dispensing by time with a pre-set pau

Pagina 23

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM3ContentsDispensing by volume within a pre-set time 27Intermittent dispensing by volume 28 by time

Pagina 24

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM30HinweisMit RUN/STOP kann die Dosierung unterbrochen und danach wieder fortgeführt werden.Mit RESET kann

Pagina 25

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM31Drip-free dispensingReverse piston strokes allow drip-free dispensing (1 to 100 strokes)See basic setti

Pagina 26

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM32Pumping against pressureThe REGLO-CPF Digital can be used for continuous duty at a dif-ferential pressu

Pagina 27

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM33Analog interfacePin 4: +5VDCFor connecting an external control unit (current <100mA). Pin 5: GNDPoin

Pagina 28 - (Volumen)

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM34 HinweisDie REGLO-CPF Digital hat beim Einschalten eine Verzögerung von 5 Sekunden, bis die serielle

Pagina 29 - (Zeiteinheit)

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM35Serial interfaceRS232 OUT (male)Pin 2: RS232 RxIs used for connecting additional pumps together with pi

Pagina 30

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM36Serielle Schnittstelle / Serial interface / Interface sérielle Befehl Funktion / Beschreibung B

Pagina 31 -  Erste Dosierung verwerfen

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM37Serielle Schnittstelle / Serial interface / Interface sérielleBefehl Funktion / Beschreibung Beispiel

Pagina 32

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM38Serielle Schnittstelle / Serial interface / Interface sérielleBefehl Funktion / Beschreibung Beispiel

Pagina 33

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM39Serielle Schnittstelle / Serial interface / Interface sérielleBefehl Funktion / Beschreibung Beispiel

Pagina 34

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM4W I C H T I G IMPORTANTPiston pump-heads require thorough flus-hing after useWe recommend to flush the pum

Pagina 35

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM40Serielle Schnittstelle / Serial interface / Interface sérielleBefehl Funktion / Beschreibung Beispiel

Pagina 36

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM41Cascading several pumpsProviding that an appropriate soft-ware is available, up to8 ISMATEC® pumps can

Pagina 37

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM42lµ52–2010IMF/900IMFlµ05–5500IMFlµ001–01700IMFedoC-DI5205001nim1–nim/tmpr040081040081040081buH/emuloVeko

Pagina 38

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM43AccessoriesFoot switch Order No. ISM 894This foot switch serves as a start/stop device.It is very use

Pagina 39

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM44Service and repairsLike all pumps, the REGLO-CPF Digital contains components that will wear over a peri

Pagina 40

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM45Replacement partsFor repairs you intend to carry out by yourself (out of the warranty period), you can

Pagina 41

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM46 HinweisBeachten Sie ebenfalls unsere Ga-rantie- und allgemeinen Verkaufs- und Lieferbedingungen.Bitt

Pagina 42 -  Remarque

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM474cbbc1aRH00RH0RH1443245Montage eines Keramikkolben-kopfes auf den Antrieb REGLO-CPFAssembly parts from

Pagina 43

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM481 Attaching the mounting plate Remove screws (b) and serra-ted lock washers (c) from the pump-head.2

Pagina 44 -  Attention

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM49Montage eines Keramikkolben-kopfes auf den Antrieb REGLO-CPF6 Die 4 Senkschrauben (4) festziehen. Die

Pagina 45

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM5 HinweisWir empfehlen, diese Betriebsanlei-tung genau durchzulesen. Beim Betrieb einer Pumpe sind gewi

Pagina 46

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM50

Pagina 47

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM51

Pagina 48

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM52ISMATEC® Vertretung / Representative / ReprésentationISMATEC® - Ihr kompetenter Partner für anspruchsv

Pagina 49

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM6Safety precautionsMedia containing particles:We recommend you to rinse the pump-head after every pum-pin

Pagina 50

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM7Safety precautions Only new fuses, according to the specifications stated on page 10 in this manual, mu

Pagina 51

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM8Warranty termsWe warrant the perfect functio-ning of our products, provided they have been installed and

Pagina 52 - +49(0) 93 77 / 13 88

REGLO-CPF Digital/ISMATEC SA/8.12.06/CB/GP/TM9Product The REGLO-CPF Digital is a valve-less rotary piston dispensing drive.Package: Pump drive ISM 3

Comentarios a estos manuales

Sin comentarios